LGB系列燃气燃烧器控制器
品牌:SIEMENS(西门子)
产地:德国
描述:
-用于控制单级或双级燃烧器的控制
-燃烧控制器符合676和EN298
-通常与使用离子棒检测火焰信号或者通过AGQ1辅助模块与UV连接
-点火阀可控制
-具有低电压监测
-具有远程复位
-LGB41...用于大气式燃烧器
机械式燃烧控制器用于控制单段或双段燃气或气/油间歇运行的小型(小于350KW)燃烧器具有远程复位,低电压监控,空气压力检测等控制功能
|
产品介绍
|
The LGB... burner controls are used for the startup and supervision of single- or 2-stage gas or gas / oil burners in intermittent operation.Depending on the type of burner control used, the flame is supervised either by an ionization probe, a blue-flame detector QRC1... for forced draft gas / oil burners, or a UV detector QRA... (with auxiliary unit AGQ1...A27).
In connection with the respective adapters, the LGB... burner controls replace their predecessor types LFI7... and LFM1... (also refer to ?Replacement types under Ordering).
-
Automatic forced draft burners for gaseous fuels to EN 676
-
Gas burner controls to EN 298
-
Undervoltage detection
-
Air pressure supervision with functional check of the air pressure monitor during startup and operation
-
Electrical remote reset facility
-
LGB41... for use with atmospheric gas burners
|
型号表
|
型号
|
认证
|
tw/s
|
t1/s
|
TSA/s
|
t3n/s
|
t3/s
|
t4/s
|
t9/s
|
t10/s
|
t11/s
|
t12/s
|
t20/s
|
LGB21.130A27
|
CH,EU,S,SF
|
8
|
7
|
3
|
2.4
|
2
|
8
|
-
|
5
|
-
|
-
|
6
|
LGB21.230A27
|
CH,EU,S,SF
|
8
|
15
|
3
|
2.4
|
2
|
8
|
-
|
5
|
-
|
-
|
38
|
LGB21.330A27
|
CH,EU,H,S,SF
|
8
|
30
|
3
|
2.4
|
2
|
8
|
-
|
5
|
-
|
-
|
23
|
LGB21.350A27
|
CH,EU,H,S,SF
|
8
|
30
|
5
|
4
|
2
|
10
|
-
|
5
|
-
|
-
|
2
|
LGB21.550A27
|
AUS,DH,EU
|
8
|
50
|
5
|
4
|
2
|
10
|
-
|
5
|
-
|
-
|
2
|
LGB22.130A27
|
CH,EU,N,S
|
9
|
7
|
3
|
2.4
|
3
|
8
|
-
|
3
|
12
|
12
|
21
|
LGB22.230B27
|
CH,EU,N,S,SF
|
9
|
20
|
3
|
2.4
|
3
|
8
|
-
|
3
|
16.5
|
16.5
|
2
|
LGB22.330A27
|
AUS,CH,EU,H,N,S,SF
|
9
|
30
|
3
|
2.4
|
3
|
8
|
-
|
3
|
12
|
11
|
2
|
LGB22.330A270
|
EU
|
9
|
30
|
3
|
2.4
|
3
|
8
|
-
|
3
|
12
|
11
|
2
|
LGB32.130A27
|
CH,EU
|
9
|
7
|
3
|
2.4
|
3
|
8
|
-
|
3
|
12
|
12
|
21
|
LGB32.230A27
|
CH,EU
|
9
|
20
|
3
|
2.4
|
3
|
8
|
-
|
3
|
16.5
|
16.5
|
2
|
LGB32.330A27
|
CH,EU
|
9
|
30
|
3
|
2.4
|
3
|
8
|
-
|
3
|
12
|
11
|
2
|
LGB32.350A27
|
CH,EU
|
9
|
30
|
5
|
4.4
|
1
|
10
|
-
|
3
|
12
|
9
|
2
|
LGB41.255A27
|
EU
|
18
|
-
|
5
|
4
|
2
|
10
|
5
|
-
|
-
|
-
|
10
|
LGB41.258A27
|
CH,EU,H,SF
|
18
|
-
|
5
|
4
|
2
|
10
|
9
|
-
|
-
|
-
|
10
|
|
tw
|
等待时间
|
t1
|
预吹扫时间
|
TSA
|
点火安全时间
|
t3
|
预点火时间
|
t3n
|
后点火时间
|
t4
|
电磁阀1到电磁阀2的间隔时间,或电磁阀1到比例控制开始的间隔时间
|
t9
|
第二安全时间(仅LGB41...)
|
t10
|
空气压力信号建立时间
|
t11
|
伺服马达程序打开时间
|
t12
|
伺服马达程序关闭时间
|
t20
|
自锁定后的程序内部循环时间
|
|
|
技术参数
|
主要参数
|
主电压
|
AC220V -15%...AC240V +10%(LGB2../LGB4...)
|
AC230V -15%/+10%(LGB32...)
|
AC100V -15%...AC110V +10%
|
主频率
|
50...60Hz ±6%
|
外部保险丝
|
10A
|
功率
|
3VA
|
重量
|
230g
|
保护等级
|
IP40
|
额定电流
|
|
端子3
|
3A(可在0.5S内到15A)
|
端子4,5,7
|
2A
|
端子9,10
|
1A
|
端子12
|
5A
|
|
|
|
环境条件
|
运输环境
|
IEC 721-3-2
|
内部条件
|
class 2K2
|
温度范围
|
-50...+60ºC
|
机械条件
|
class 2M2
|
湿度
|
<95%
|
运行环境
|
IEC 721-3-3
|
内部条件
|
class 3K5
|
机械条件
|
class 3M2
|
温度范围
|
-20...+60ºC
|
湿度
|
<95%
|
不得进水
|
|
|
|